{"id":909,"date":"2017-09-16T11:24:21","date_gmt":"2017-09-16T11:24:21","guid":{"rendered":"https:\/\/www.acm-sl.com\/?page_id=909"},"modified":"2017-09-16T11:27:41","modified_gmt":"2017-09-16T11:27:41","slug":"registrador-para-plantas-fotovoltaicas","status":"publish","type":"page","link":"https:\/\/www.acm-sl.com\/catalog\/instrumentacion\/registrador-para-plantas-fotovoltaicas","title":{"rendered":"Registrador para Plantas Fotovoltaicas"},"content":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243; _builder_version=&#8221;3.0.47&#8243;][et_pb_row _builder_version=&#8221;3.0.47&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; _i=&#8221;0&#8243; _address=&#8221;0.0&#8243;][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.0.75&#8243; background_layout=&#8221;light&#8221; border_style=&#8221;solid&#8221;]<\/p>\n<h3>\u00bfQu\u00e9 pasa en su planta en los momentos de baja luminosidad, al alba o al ocaso? \u00bfCu\u00e1ntas veces entran y salen de Producci\u00f3n sus Inversores?<\/h3>\n<p>Cuando el nivel luminoso est\u00e1 cercano al umbral de entrada en funcionamiento de los inversores ocurre que peque\u00f1as variaciones &#8211; debidas a nubes, por ejemplo &#8211; hacen que estos entren y salgan de funcionamiento un n\u00famero importante de veces: un comportamiento que reduce la vida de los mismos; adem\u00e1s estos se producen cuando la producci\u00f3n no es alta.<\/p>\n<h3>\u00bfC\u00f3mo responden los Inversores a cambios bruscos en la tensi\u00f3n de la Red El\u00e9ctrica? \u00bfC\u00f3mo responden a Huecos de Tensi\u00f3n?<\/h3>\n<p>La legislaci\u00f3n exige un comportamiento frente a las bajadas y subidas de tensi\u00f3n muy exigente, que influye en la vida esperable de los Inversores.<\/p>\n<p>Nuestro equipo <strong>ECF<\/strong> (<em>Equipo de Caracterizaci\u00f3n Fotovoltaica<\/em>) usa la misma tecnolog\u00eda que nuestro DL1300, combinada con equipos de monitorizaci\u00f3n de la Red El\u00e9ctrica de alta resoluci\u00f3n, y registra los par\u00e1metros claves que permiten analizar en detalle las condiciones de funcionamiento de la planta, y el comportamiento de los Inversores.<\/p>\n<figure id=\"attachment_914\" aria-describedby=\"caption-attachment-914\" style=\"width: 1024px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.acm-sl.com\/wp-content\/uploads\/2017\/09\/Esquema-ECF.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-914\" src=\"https:\/\/www.acm-sl.com\/wp-content\/uploads\/2017\/09\/Esquema-ECF-1024x723.png\" alt=\"Esquema Registrador Fotovoltaica ECF\" width=\"1024\" height=\"723\" srcset=\"https:\/\/www.acm-sl.com\/wp-content\/uploads\/2017\/09\/Esquema-ECF-1024x723.png 1024w, https:\/\/www.acm-sl.com\/wp-content\/uploads\/2017\/09\/Esquema-ECF-300x212.png 300w, https:\/\/www.acm-sl.com\/wp-content\/uploads\/2017\/09\/Esquema-ECF-768x543.png 768w, https:\/\/www.acm-sl.com\/wp-content\/uploads\/2017\/09\/Esquema-ECF-1080x763.png 1080w, https:\/\/www.acm-sl.com\/wp-content\/uploads\/2017\/09\/Esquema-ECF.png 1158w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption id=\"caption-attachment-914\" class=\"wp-caption-text\">Esquema Registrador Fotovoltaica ECF<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243; _builder_version=&#8221;3.0.47&#8243;][et_pb_row _builder_version=&#8221;3.0.47&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; _i=&#8221;0&#8243; _address=&#8221;0.0&#8243;][et_pb_column type=&#8221;4_4&#8243;][et_pb_text _builder_version=&#8221;3.0.75&#8243; background_layout=&#8221;light&#8221; border_style=&#8221;solid&#8221;] \u00bfQu\u00e9 pasa en su planta en los momentos de baja luminosidad, al alba o al ocaso? \u00bfCu\u00e1ntas veces entran y salen de Producci\u00f3n sus Inversores? Cuando el nivel luminoso est\u00e1 cercano al umbral de entrada en funcionamiento de los inversores ocurre que [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":161,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-909","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/pages\/909","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/comments?post=909"}],"version-history":[{"count":4,"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/pages\/909\/revisions"}],"predecessor-version":[{"id":915,"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/pages\/909\/revisions\/915"}],"up":[{"embeddable":true,"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/pages\/161"}],"wp:attachment":[{"href":"https:\/\/www.acm-sl.com\/catalog\/wp-json\/wp\/v2\/media?parent=909"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}